| Products |
|
 |
Medical Ultra Low Temperature Freezer |
|
|
|

|

|
Click to enlarge image
|
Model Number |
DFU-014 /FU-014 , DFU-015 / FU-015 |
Feature
- CFC FREE refrigerates system for laboratory products by introducing our first field-tested freezers.
- Giant Star validation testing service in advance of shipment can accelerate in house KFDA installation Qualification programs upon delivery.
- Ultra Low Temperature Freezer with energy saving refrigeration system that run only on demand while maintaining temperature -86 Ë C.
- The temperature of the upper and lower limits are changeable only after the input of the password number.
- With a minimum 125mm of polyurethane foam insulation in the cabinet walls and bottoms.
- All the temperature are controller as preciously as 0.5 Ë C with a contactless SSR and are serin a unit of 1 degree Ë C
- The temperature of the upper and lower limits can be set for alarm.
- A real PC controller, a set temperature, and temperature of the upper and lower limits are displayed on the LED digital. RS-232 data port.
- In case of power failure, back-up battery can supply electricity to the controller at least for 72Hours in case of power failure, a power alarm system goes into action by a back-up battery.
- If lost dust become accumulated on the radiator a dust sensor makes an alarm sound.
- An alarm sounds if the supplied power voltage is lower than the appropriate level.
- An alarm sounds if an undesirable condition occurs at the primary or secondary compressor of a refrigerator.
- The remaining capacity of the back-up battery and the level of the supplied power voltage can be checked.
- A mock test on the alarm function for the higher or lower temperature beyond a limit can be performed.
- The high density polyurethane foamed under the high pressure gives excellent adiabatic effect of the chamber.
- The silicon gaskets corrugated triply does not allow any leaking from the ultra low temperature freezer chamber.
- Interior material : Stainless Steel #304 plate.
- Exterior Material : Expose polyurethane coating steel.
Specification
| Model |
DFC-014 |
FU-014 |
DFU-015 |
FU-015 |
| Set Temperature |
-50 Ë C to -86Ë C/ -10Ë C to -40Ë C |
50 Ë C to -86Ë C -10Ë C to -40Ë C |
| |
| Capacity |
387 liter |
483 liter |
| |
| In size Dimension |
W 620 X H 1,200 X X0mm |
W 620 X H 1,200 X D 650mm |
| |
| Out size Dimension |
W 860 X H 1,920 X D 660mm |
W 860 X H 1,920 X D 800mm |
| |
| Interior |
Stainless Steel #304 |
Stainless Steel #304 |
| |
| Exterior |
Galvanized Steel Plate (SECC) |
Galvanized Steel Plate (SECC) |
| |
| Condensing Unit |
1/2Hp, Hermetically X 2 / 1/2Hp, Hermetically |
3/4Hp, Hermetically X 2 / 3/4Hp, Hermetically |
| |
| |
Two Compressor / One Compressor |
Two Compressor / One Compressor |
| |
| Refrigant |
CFC FREE 1 st R-134a, 2st R-23Mic |
CFC FREE 1 st R-134a, 2st R-23Mic |
| |
| Display Control |
PC Microprocess Control V.F.D.(Vacuum Fluorescent Display) Control, PV Temp
|
PC Microprocess Control V.F.D.(Vacuum Fluorescent Display) Control, PV Temp
|
| |
| |
SV Temp, Hi Limit Temp, Low Limit Temp, 4Alarm lamp. |
SV Temp, Hi Limit Temp, Low Limit Temp, 4Alarm lamp. |
| |
| Alarm |
Door open / Condenser / Compressor / Temperature |
Door open / Condenser / Compressor / Temperature |
| |
| Insulation |
125mm, Thick Polyurethane Foam |
125mm, Thick Polyurethane Foam |
| |
| Power Source |
AC 220V, 50/60Hz, 1Ph |
AC 220V, 50/60Hz, 1Ph |
| |
| Recorder(Option) |
7Days, Thermo Printer |
7Days, Thermo Printer |
| |
| |
|
|
|
|
| |
|
|
|